HEATING EXCHANGER  "COMPACT LINE" |
![]() |
HALVED PRICE |
Data / Model |
AS 365 |
LC 650 |
Thermal power Kcal(Kw)/hour Minimum : Maximum : |
  163.000 (188) 365.000 (423) |
  163.000 (188)   650.000 (750) * |
Drying air temparature (Over ambient temperature) Minimum. :>Maximum. : |
  35 ° C 85 / 90 ° C ** |
  25 ° C 100 / 110 ° C ** |
Thermal performance : |
90 % - 94 % ** |
90 % - 94 % ** |
Suitable for driers Mod. : |
Junior / Super 90 / 100 / 120 |
Large 180 / 200 / 240 |
Note: * - Suitable even in option Kcal 730.000 (845 Kw) with supply of an extra burner fan-pump unit of larger size. ** - The data about maximum temperatures and performances are largely depending, further the level of ambient temperature, even of the relative humidity level of the air |
||
![]() |
Made fully in stainless Inox steel using three different qualities of steel to get the best thermal performing in each section. |